Computer Room Hot?
Anonymous Coward writes "Here is a cool PC ventilation product I ran across. Like many faithful on here, I have multiple computers in a small room which really heat up the place. My office is a good eight degrees warmer than the rest of the house This product called R.A.C.H.A.L (Reduce Annoying Computer Heat And Loudness) vents computer exhaust into the wall, not the room. Might cut down on the electricity bills during those hot months.." Another approach: An anonymous reader writes "If your 'puter is getting to loud, you might want to consider some silent cooling. And the gang at OverclockersClub has just that. A three page review of the Zalman VGA Heatpipe Cooler. This thing is pretty nice looking, and with no power, no noise, what else could a guy ask for? Check out the review here. How come more companies don't do the "silent" thing?" Borked link fixed.
The cavity at any given point in your wall, if it's to code, is about two cubic feet, surrounded by wood and plaster. Unless you had a magically powerful fan in your PC you won't be getting any circulation at all, because you're pressurizing a fixed cavity. Furthermore, the tube isn't insulated. This is a really silly idea. However, if you vented it *outside*, then you're talking something useful.
--Mike
this is woefully unimpressive, and uninspired.
...if i ever find a fridge and hook this up, i'll be sure to post pictures :)
first off, with 16" on center stud walls, constructed of 2x4s, and an average studheight of 92 and 5/8ths inches, you can see that the volume inside a stud wall "cell" is pretty piss poor - roughly 5800 cubic inches.
There are a few issues that make this "solution" stupid.
1) the heat doesn't go anywhere. there should be a correspondingly large diameter cut out in the top plate of the wall, so that the air can escape in the attic (where it might do some good, as the attic is cold and properly ventilated, unlike the interior of a wall)
2) there may be cold water supply pipes in wall. do you want to heat your cold water ? especially if they're copper pipes with a very effective heat transfer characteristic
2a) there may be runs of NM-B (romex) electrical cable in that wall cell. The ampacity of electrical wire is a function of its rated capacity, and while most ampacity ratings are given up to 70C, if this thing were _seriously_ efficient at cooling a computer, then it would perhaps begin to cause problems with in-wall structures
3) how does the national fire code feel about stuffing heat into closed interior walls (made of flame-retardant drywall, typically)
4) if the excess heat it dispells isn't enough to cause any code violations, then it clearly isn't sucking enough heat to be worth installing
5) this does little to eliminate the overall heat+noise of _systems_
My idea for this was to find an abandoned refrigerator, or better yet, freezer, and just putting whole systems inside there, and then running flue-spec double-walled exhaust vent pipe elsewhere. Having all the PCs stuck inside a fridge/freezer (shut off, of course) that was properly vented should make things cool _AND_ quiet. Don't beleive me ? Try putting your battery powered alarm clock in your freezer, and see if you can still hear it once the door shuts. You want whole-system noise cancellation ? Then you need real insulation. Want to keep your office cool? then you'll need to do a lot more than putting a turbluent undersized vacuum hose on the back of your PC.
My opinions are my own, and do not necessarily represent those of my employer.
Actually, I think it's even worse than you (Greedo) suspect. Elance appears to be a site where "freelancers" bid to provide services in response to project posts (i.e., reverse bidding). I think your google sleuthing uncovered that the anonymous poster won the bid for this "Web Template & Graphic design" project from Computer Exhaust Systems. I wonder if submitting this Slashdot story was part of the deal and, if so, whether they got a success fee when it actually got posted!