Cooler Servers or Cooler Rooms?

mstansberry writes "Analysts, experts and engineers rumble over which is more important in curbing server heat issues; cooler rooms or cooler servers. And who will be the first vendor to bring water back into the data center?"

11 of 409 comments (clear)

  1. Aquafina... by vmcto · · Score: 5, Funny

    Will probably be the first vendor to bring water into the datacenter... I believe I've seen evidence in some datacenters already.

    1. Re:Aquafina... by _Sharp'r_ · · Score: 5, Interesting

      Well, since my last company had most of their servers in a data center room where we had two different floods, I'd say I have a pretty good idea which hosting company will be the first to bring water into the data center ...

      The first problem was snow that piled up outside, combined with clogged drains, that led to melting snow coming in through the wall where some pipes entered/exited. Since their layout was power in the floor and networking in the ladder racks, it's actually pretty amazing that a large portion of the power plugs and switches still worked, even while being submerged in 6 inches of water.

      So about a year after they had taken care of that issue, a water pipe for a bathroom on the floor above burst, and of course the water came down right in our room in the hosting center. It wasn't so bad until the flourescent lights in the ceiling filled up and started to over flow. We were able to limit the damage by throwing tarps over the tops of all the racks (there goes your cooling effect, though), but we still lost about 100K worth of server and switching equipment.

      So yeah, water in the data center? It's been done.

      --
      The party of stupid and the party of evil get together and do something both stupid and evil, then call it bipartisan.
  2. well I've always wondered this by Saven+Marek · · Score: 5, Insightful

    I've always wondered this. why have duplication of a function in a server across every single server box when it could all be done in the environment. For example all servers get electricity from the server room and all servers get network from the server room so why not all servers get cooling from 10F cooling in the server room.

    It makes sense!

    1. Re:well I've always wondered this by T-Ranger · · Score: 5, Insightful

      What I have never understood is why servers virtually always have AC power supplies. Yes, you can get NEBS(?) compliant servers that take DC, but this isnt really a general option, but a distinct model line compleatly.

      UPSs take AC, turn it to DC, charge their batteries. A sepearate system takes DC from batteries, inverts it and sends out AC. (Good UPSs, anyway. Otherwise they are "battery backups", not uninteruptable) Computer power supplies take AC and distribute DC inside the case. WTF?

      Why doesn't APC start selling ATX power supplies? Directly swap out AC powersupplies, have them plug into the DC providing UPS and/or per-rack (or even per-room) powersupplies.

      Electrical codes are a BS excuse. Even if you needed verdor specific racks, a DC providing rack is, so far as the fire marshal should be concerned, just a very large blade enclosure, which are clearly acceptable.

      I cant beleive that Im the first one to ever come up with this idea. So there must be some problem with it.... Some EE want to explain why this wouldnt work?

  3. If you have cooler servers... by havaloc · · Score: 5, Insightful

    ...you won't need as much cooling in the room. Easy enough. This will save a ton of money in the long run, not to mention the environment and all that.

  4. inevitability breeds contempt by icebrrrg · · Score: 5, Interesting

    "Roger Schmidt, chief thermodynamics engineer at IBM, [recently] admitted that, while everyone knows servers are one day going to be water-cooled, no one wants to be first, believing that if their competitors still claim they are fine with air cooling, the guy who goes to water cooling will rapidly drop back in sales until others admit it is necessary."

    you know, some times the market actually rewards innovation. tough to believe, i know, and this isn't innovation, it's common sense, but mfg's are afraid of this? come on, people, the technocenti have been doing this for their home servers for a long, long time, let's bring it into the corporate world.

    --
    nothing worth possessing isn't possessed. or something.
  5. Re:Why not both? by Anonymous Coward · · Score: 5, Insightful

    Cost.

    The question isn't whether it's good to keep both cool. The question is, which makes more financial sense? Cooling the whole room? Spending the money to purchase servers with a low heat-to-computation ratio?

    Probably a combination. But to say that people should equip every computer with VIA ultra-low-power chips _and_ freeze the server room is silly.

  6. Water cooling, pah! by hazee · · Score: 5, Funny

    Water cooling? Pah! Why not take a leaf out of Seymour Cray's book - build a sodding great swimming pool, fill it with non-conductive freon, then just lob the whole computer in.

    Also has the added benefit that you can see at a glance which processors are working the hardest by looking to see which are producing the most bubbles.

    Wonder if you could introduce fish into the tank and make a feature of it? If you could find any freon-breathing fish, that is...

  7. Cooler servers... by Aphrika · · Score: 5, Insightful

    From experience of aircon failing/breaking.

    At least if a server fails it's one unit that'll either get hot or shutdown which means a high degree of business continuity.

    When your aircon goes down you're in a whole world or hurt. Ours went in a powercut, yet the servers stayed on because of the UPSes - hence the room temperature rose and the alarms went off. Nothing damaged, but it made us realise that it's important to have both, otherwise your redundancy and failover plans expand into the world of facilities and operations, rather than staying within the IT realm.

  8. Reminds me of an amusing anecdote by Raul654 · · Score: 5, Funny

    About 4 years ago, I was touring the US National Supercomputing Center in San Diego. One of the supercomputers had a clear plexiglass side where you could see inside, and it had running water and even a waterfall. Mind you, this 'water' was running directly over the electronic components. So the guy doing the tour said that it wasn't really water, but a chemical compound similiar to water, but very nonconductive. He tells us that it costs $10,000 per barrel, and that he always gets questions about what happens if you drink it. "Well, we're not sure what happens if you drink it, but we figure one of two things will happen. It could be toxic, and you drink it and die. Or, it could be nontoxic, and when our finicial guys found out you were drinking their $10,000-a-barrell water, they'll kill you."

    --


    To make laws that man cannot, and will not obey, serves to bring all law into contempt.
    --E.C. Stanton
  9. Water-chilled Cabinets Already In Use for Blades by miller60 · · Score: 5, Informative
    Liebert and Sanmina have been selling blade server cabinets that use chilled water for at least three years. Vendors and data center operators have been wrestling with the heat loads generated by blade servers since 2001, and the dilemma of how to cool high-density "hot spots" has caused many tech companies to wait on buying blades to replace their larger servers. That's changing now, driven by the need to save costs with more efficient use of data center space.

    The industry has taken a two-pronged approach. Equipment vendors have been developing cabinets with built-in cooling, while design consultants try to reconfigure raised-floor data center space to circulate air more efficiently. The problem usually isn't cooling the air, but directing the cooled air through the cabinet properly.

    There was an excellent discussion of this problem last year at Data Center World in Las Vegas. As enterprises finally start to consolidate servers and adopt blade serves (which were overhyped for years), many are finding their data centers simply aren't designed to handle the "hot spots" created by cabinets chock full of blades. Facilities with lower ceilings are particularly difficult to reconfigure. The additional cooling demand usually means higher raised floors, which leaves less space to properly recirculate the air above the cabinets. Some data center engineers refer to this as "irreversibility" - data center design problems that can't be corrected in the physical space available. This was less of an issue a few years back, when there was tons of decent quality data center space available for a song from bankrupt telcos and colo companies. But companies who built their own data centers just before blades became the rage are finding this a problem.