How a Wiring Rack Should Look
Julie Jacobson writes, "It's so much fun to deride some of the worst home wiring jobs in existence. But once in awhile, we should salute some of the cleanest, most perfectly labeled cabling jobs in U.S. homes. At the recent CEDIA Expo, the association for home-technology integrators handed out awards for the Best Dressed Systems, each featuring miles of cable, hundreds of connectors, tons of steel, and a clean aesthetic that could make the most finicky designer swoon. Show them to your own installer for inspiration."
I know this is not going to be a popular opinion but..
Tightly bound cable bundles at the rack are NOT helping anyone but the anal person looking at the pretty pictures. Try troubleshooting or replacing a wire in that bundle at the rack. A rack is a dynamic environment, that is why there are jacks there! If it was not meant to be dynamic, why even use jacks at the rack? Just hard wire everything. If your rack is attached to the floor, movement and cable chafing is not a problem either. If you have to spend more then 5 minutes to get the bundle the way it looked before you replaced a wire at the rack level, you are wasting every ones time including your own to get it to look absolutely perfect. There is NOTHING wrong from a technical standpoint by using the plain old cable management hooks on the front of a typical rack that the cables route through, each wire does not need to be zip tied or Velcro every few inches and each wire spreading off of the bundle with a cable tie for each one, in fact, you can cross over the width of a typical 19 inch rack without the need for any additional bundling other then standard wire management trays and hooks. Side rack mounting depends on type of management you have for that, I've seen some better then others.
Like I said, my opinion is not going to be a popular one but can someone give me a technical reason why every rj45 plug in something like a 24 port blade needs to tied individually or even in groups of two? Is that "unsafe"? Is it a hazard in your environment? If so, what the hell is going on in your equipment room and why do you not have a door on your rack? Is it harder to track down then a huge bundle 20 deep and zip tied to 10ft lbs every 3 inches?
Oddly enough, I've seen many installations where the rack looked pristine but the out of sight areas or covered parts for the actual runs like under floor or overhead in partially covered trays or inside the rack vertical sections looked like spaghetti. If your goal is neatness and you justify the clean rack area for some technical reason, what is your excuse for the other areas that are out of normal sight looking like crap, do those technical reasons for a pristine rack not apply to areas others can not easily see? In order to get the rack to look nice, the extra cabling is balled up and hidden elsewhere. It does not make sense.
For reference, I do neat work now and I've had to replace and re bundle cables and wires inside nuclear reactor instrumentation control panels and rack mounted electronic instrumentation shelves using nylon string and shellac so I am very familiar with the concept and the goals of proper wire management.