New Type of Atomic Microscope On the Way

Iddo Genuth writes "Researchers at the Surface Science Laboratory at Universidad Autonoma de Madrid have created an ultrasmooth mirror that could be used to create a revolutionary new atomic microscope within the next several years. The new atomic microscope — using helium atoms for imaging — has the potential to provide the same resolution as existing electron microscopes but without many of the problems which have plagued them for years."

3 of 50 comments (clear)

  1. I did this 14 years ago by Auckerman · · Score: 3, Informative

    This isn't a new type of microscope, this is actually kind of old. I was working in a lab doing this as an undergrad in 94. It really only works with very smooth (as in atomic level smooth) crystalline structures. You can build 3-d data, that's for sure, but only by growing them and watching them build as you shoot helium at it (via rotating the mirror and watching the diffraction). Purely surface chemistry "simple" crystals. Unless for things like protein structures, where X-ray is the way to go.

    What these guys did was merely figure out a way to reflect helium better, so you get more exact data the first time around, rather than having to run the same test over and over and doing averages to get rid of the noise. Good for science, sure, but hardly a new microscope.

    --

    Burn Hollywood Burn
  2. Re:Already done by kaneod · · Score: 5, Informative

    Yep, the idea is to use neutral atoms. Actually people tend to get a bit hung up on the resolution issue - it is true that it is an absolute pain to both focus and detect neutral helium, and other microscopies offer better ultimate resolution.
    However, what things like helium ion microscopy and scanning electron microscopy don't offer is absolute surface sensitivity, with almost no damage. An SEM can only be used with conducting samples (yes, you can gold or graphite coat stuff but if you're interested in the surface you're still stuffed) and the beam penetrates a good 30-100 atomic layers so the *surface* resolution is quite limited. Helium ion microscopy is better in that regard but still penetrates quite a few atomic layers and will still damage the surface.
    In short, if you're interested in delicate or reactive surfaces, neutral helium is probably the only way to go. The initial resolution won't be great (I believe they're still aiming initially for sub-optical, rather than atomic ;o) ) but that's not really the point.

  3. Re:Pardon my ignorance but... by upside · · Score: 3, Informative

    Ignorance is OK. Not reading the article before posting is ... Slashdot.

    Here, let me help you:

    The high speed electrons used in the electron microscope <nah nah nah> making it difficult to get accurate results and impossible to repeat tests.

    --