Ask Slashdot: Building A Server Rack Into a New Home?

jawtheshark writes "I'm building a house, and obviously I want a modest network built-in. Nothing fancy, two RJ-45 per room, four in the living room, and that's basically it. I already got myself a rack mountable Cisco Small Business switch and I have a self-built 4U server (low-power, won't make much heat) which can be rack mounted (505mm deep). Now, the construction company suggests a wall mounted rack (6U: 340mm x 600mm x 480mm — 6U definitely won't be enough, but a 12U model exists). It's not expensive, but I have never worked on a rack where the backside is unreachable. (For work, I get to work in a data center with huge racks that are accessible from both sides). Now obviously, I don't need a data center-grade rack, but these wall-mounted racks scream 'switch-only' racks to me. What are your experiences? Is it possible to put servers in racks like these, or should I find a 'both-side-accessible' rack instead?"

3 of 402 comments (clear)

  1. Re:Another suggestion.. by Anonymous Coward · · Score: 5, Insightful

    Running open ended pvc pipe could be a building code violation. At the very least, you'd have to look into fire blocking the ends after installation. Even with plenum rated cables, you could be denied for a fire claim due to this 'neat' addition.

  2. Re:Go with fiber optic by Shoten · · Score: 5, Insightful

    Dude, if you think the future of connectivity is fiber, you need to leave the 90s and come join us here in 2012. I'm not sure what's so 'future proof' about a relatively temperamental connectivity media that is supported by exactly *no* household devices, and very few wifi access points. As for the "future," I would point out that every high-speed LAN technology started as fiber and then became copper...because fiber is a colossal pain in the ass compared to copper. When something consistently goes from one thing to another, this is called a "trend," and trends tell you about the future. It ain't fiber.

    --

    For your security, this post has been encrypted with ROT-13, twice.
  3. Re:42U - Go Big or Go Home by xQx · · Score: 5, Insightful

    Couldn't agree more.

    To answer the poster's direct question: Yes, I have dealt with racks that you can't get to the back of. I've dealt with racks that have the vertical rails integrated into the sides. I've dealt with half-height racks, wall mounted racks that swing out so you can get to the back of them, and I've dealt with home-made racks that have rails that bend when you hang a server from the front. I've also worked with Compaq servers with mounting brackets that don't work unless your rails are exactly the right distance apart front-to-back (meaning you need to tear down a whole rack to re-position the rails, to mount one bloody server).

    I have the following advice:

    1. DO NOT BUY WALL MOUNTED RACKS (unless you are a large corporate or a public building).
    They are ugly as sin, they are never deep enough, and in a small-business or home environment they are only good for bumping heads on. If they swing out, half the time the installer hasn't accounted for the full weight of a loaded rack and it feels like it's going to fall off the wall.They are not built to deal with the heat of POE switches, let alone servers. Unless you need the security given by them, it's cheaper, more attractive and more accessible to mount a switch vertically on a wall or in a cupboard.

    2. DO NOT BUY HALF-HEIGHT RACKS (unless you desperately need the space)
    They cost almost as much as full-height racks, they often get replaced with full-height racks after 2 years because they get full - in the end they are almost never worth it.

    3. LOOK VERY CLOSELY AT CHEAP RACKS
    A good rack will last you 10 years. A bad rack will last you 20 years and piss you off every time you go near it. Imagine mounting a full-depth POE switch to the front rail of a rack, then seeing that the back of the switch is about 2RU lower than the front, because the front vertical rail has bent under the weight. That's what happens when they make the vertical rails out of 1mm low tensile steel, not 2mm high tensile steel. Or, imagine having a server or router that has decided to put a RJ45 port on the front (usually an iLo port) and you find you have to either leave a whole RU free above the server to run the cat-5 cable back. Welcome to the joys of an APC rack, where the vertical rails are moulded to the edge of the rack.

    4. AT HOME - USE A CABINET MAKER
    If you want the best & cheapest solution - I'd build a cupboard big enough for you to put a second hand 42RU rack on wheels into it, and terminate your RJ45's on 6-gang wall outlets at the top of the cupboard. For cooling, put a vent in the top of the door and run a ducted air-con duct to the bottom of the cupboard. Then you just roll your rack out when you need it, to guests it looks like a cupboard, and the next home owner will turn it into a linen closet.
    But, if you want something that looks a million dollars, I would take the internal steel of a comms rack and mount it on rolling cupboard rails (do the maths on the weight) and integrate it into a full-height cupboard, so when you open the cupboard door the whole rack slides out for you. If you get a friendly cabinet maker to do it while you're building the house, you would probably have the whole thing done for less than the price of an APC rack.