Hackers Gain "Full Control" of Critical SCADA Systems
mask.of.sanity writes "Researchers have found holes in industrial control systems that they say grant full control of systems running energy, chemical and transportation systems. They also identified more than 150 zero day vulnerabilities of varying degrees of severity affecting the control systems and some 60,000 industrial control system devices exposed to the public internet."
do NOT connect SCADA systems to the internet.
Anons need not reply. Questions end with a question mark.
At 30C3 someone ran a portscan on the VNC port of the entire IPv4 internet, with 'interesting' results, highlights of which included a swimming pool chemical dosing control system, various power generation and control systems, building environmental control systems, air handlers, all sorts of wild and whacky things, some of them lacking in even the rudiments of passwords never mind proper crypto....
The best one looked to me like a medium voltage distribution cabinet where the setpoints on the overload trips looked like they could be reconfigured from the internet!
Ahh the things you can do in reasonable time with a 100Gb/s of bandwidth, the rsulting slides at the closing event (which is where I ran across it) were very, very scary.
SCADA on the internet is a really, really bad thing.
73 M0HCN. :wq
It's not about sympathy, it's about the effective destruction of our entire infrastructure without dropping a single bomb. The first sign that China or Russia is at war with us will be all our utilities and factories going dark. This is everyone's concern.
The SCADA systems that I have worked with were for electrical generation and distribution and water/sewer systems, and they absolutely were air gapped. Crossing that bridge with a cable was an automatic firing offense, and yes, they canned a manager who thought that no one would notice. That utility covered an entire very large and highly-populated county and tied into the larger national electrical grid. I'll guarantee that most of the SCADA systems nationwide are air gapped, as it's required by FERC and can generate hefty fines if they're not.
"Think about how stupid the average person is. Now, realise that half of them are dumber than that." - George Carlin
My company helps critical infrastructure owners meet data sharing requirements with govt agencies. If you use certain industrial communication protocols that were established pre-internet you may be in luck. In particular, we have a unique connection that is one way, only allows the data you choose to share, and does not require any sharing of your network with the outside world or feds. To be precise, your network and the govt network come within feet of each other and our unique device creates a restricted "bridge" that only passes MB data over serial. Read only.