Hackers Gain "Full Control" of Critical SCADA Systems
mask.of.sanity writes "Researchers have found holes in industrial control systems that they say grant full control of systems running energy, chemical and transportation systems. They also identified more than 150 zero day vulnerabilities of varying degrees of severity affecting the control systems and some 60,000 industrial control system devices exposed to the public internet."
Comment removed based on user account deletion
do NOT connect SCADA systems to the internet.
Anons need not reply. Questions end with a question mark.
At 30C3 someone ran a portscan on the VNC port of the entire IPv4 internet, with 'interesting' results, highlights of which included a swimming pool chemical dosing control system, various power generation and control systems, building environmental control systems, air handlers, all sorts of wild and whacky things, some of them lacking in even the rudiments of passwords never mind proper crypto....
The best one looked to me like a medium voltage distribution cabinet where the setpoints on the overload trips looked like they could be reconfigured from the internet!
Ahh the things you can do in reasonable time with a 100Gb/s of bandwidth, the rsulting slides at the closing event (which is where I ran across it) were very, very scary.
SCADA on the internet is a really, really bad thing.
73 M0HCN. :wq
It's not about sympathy, it's about the effective destruction of our entire infrastructure without dropping a single bomb. The first sign that China or Russia is at war with us will be all our utilities and factories going dark. This is everyone's concern.
These issues have been flagged for roughly a decade. I have ZERO SYMPATHY for anyone who gets taken over.
MSOBKOW this is your boss.
What do you mean it is a security risk to put this on the internet? Everyone else has no problem doing this and I never heard of anyone being hacked. Like a billion dollar company would ever design such a thing when an internet connection is required to stay activated. Are you telling me that firewall you said we needed doesn't make is impenetrable?! Why can't you secure it? Do I need to hire someone who will?
http://saveie6.com/
Almost ALL of us that have had to deal with SCADA knew this was possible. Most of the time because incredibly stupid managers DEMAND the systems be accessible from the internet.
SCADA systems need to be airgapped completely from any network other than their own. Boo Hoo to the company that needs to buy a second set of computers for the employees to get email on. the SCADA computers are to be used ONLY for SCADA systems.
100% of the security failures lie at the feet of the managers of these facilities. Until we start beating them with sacks of doorknobs nothing will change. and yes, the SCADA infection via usb drives are the fault of management. allowing the use of USB or any other device that has not been secured and low level formatted before use on a known clean machine is the fault of management.
All USB ports should be disconnected or physically inaccessible via lock and key to users.
Do not look at laser with remaining good eye.
The problem isn't Windows (not sure if you are implying this or not). It's a convergence of factors which make patching systems a veritable nightmare in the process control systems.
1. The people who run the plant are trying to squeeze the maximum amount of yield from their plant. Shutting down a SCADA system so that it can be patched and tested may literally cost them millions of dollars per hour. Furthermore, the cost of upgrading is not looked upon kindly unless it's going to help you create more of product X at a lower price. You may argue that the greater good is more important than money but these guys aren't listening to that.
2. These industries are rife with rules and regulations that further inflate the cost of patching systems. In the pharmaceutical industry the cost of applying a single patch may run well into the millions of dollars because every change has to be meticulously audited.
3. IT is often outsourced to third parties in order to control costs. The downside of ceding control of your own infrastructure is that even something mundane like changing a firewall rule has a process which costs money and resources.
4. There is an old-school engineering mentality that is pervasive based on the old adage "if it ain't broke don't fix it". No person involved in the industry wants to find problems. They want the plant to produce and they expect the hardware and software they buy to produce - untouched - for 20-30 years.
I have seen crazy things at plant floors. Control systems still running on Windows NT, operators sharing credentials, copying files from one system to another using thumb drives because the network does not allow files-haring.
Updating breaks now with near certainty. Not updating breaks later with a lower probability. Easy choice,
Sad, but true.
I ran a part of the process plant by hand during the commisioning phase for the last automation project I was on. Working together with an operator I could barely keep up with one fifth of full capacity for four hours and we were both completely drained afterwards.
The complexity of modern process plants is mind-bogling to people who haven't seen them - and even when they've seen them they don't understand that all the valves, pumps, heat exchangers, etc., around them are doing a finely choregraphied balet behind the scenes. The manpower needed for running a process plant by hand is in the neighborhood of 10-20 times that of running an automated plant, and even then the throughput will be less and the quality of the resulting product lower.
There is an old-school engineering mentality that is pervasive based on the old adage "if it ain't broke don't fix it".
The problem with that is, by putting it on the internet, they've broken it (even if the breakage hasn't hit home yet). Nobody wants to admit that they've done that, but it's their own damn fault. A good start to fixing things would be to airgap the SCADA network from the internet, and if connecting is necessary at all, to use a good double firewall with hardened DMZ machine in between. The DMZ can be locked down hard and updated carefully, and it doesn't need to ever hold systems that need careful certifying as it should never be in the control loop; just out of band monitoring.
"Little does he know, but there is no 'I' in 'Idiot'!"
Normally the SCADA systems **ARE** air-gapped from the corporate backbone, but until we start breeding better managers some idiot will occasionally pull a cable across that gap in order to produce a report or something.
"Think about how stupid the average person is. Now, realise that half of them are dumber than that." - George Carlin
The SCADA systems that I have worked with were for electrical generation and distribution and water/sewer systems, and they absolutely were air gapped. Crossing that bridge with a cable was an automatic firing offense, and yes, they canned a manager who thought that no one would notice. That utility covered an entire very large and highly-populated county and tied into the larger national electrical grid. I'll guarantee that most of the SCADA systems nationwide are air gapped, as it's required by FERC and can generate hefty fines if they're not.