Slashdot Mirror


Should Network Cables Be Replaced?

Jyms writes "As technology changes, so hubs routers and switches are upgraded, but does the cabling need replacing, and if so, how often? Coax gave way to CAT 5 and CAT 5e replaced that. If you are running a 100Mbit/s network on old CAT 5, can that affect performance? Do CAT 5(e) cables get old?"

62 of 524 comments (clear)

  1. Cat6 by I_am_Rambi · · Score: 4, Informative

    Just like any cable, cables will break. So, yes, they do get old.

    Also, there is cat6 cables out with better specs and can handle at least up 10gb/sec.

    1. Re:Cat6 by JCSoRocks · · Score: 4, Informative

      Yeah, we've had network cables fail. Even patch cables. It's rare, but it happens. If you get the chance you might as well replace your cabling. Besides, regular CAT 5 isn't going to get you over 100Mbs - and that's no fun.

      --
      You are using English. Please learn the difference between loose and lose; they're, there, and their; your and you're.
    2. Re:Cat6 by arth1 · · Score: 5, Informative

      CAT6 is a PITA to use residentially. It is much stiffer, due to a "coffee stirrer" embedded in the middle, and doesn't bend well at all. I just downgraded from CAT6 to CAT5e for hooking portables up to my GbE LAN, just because of how unwieldy CAT6 was.
      The CAT6 plugs can also be a problem -- they are by necessity slightly thicker (the strands alternate in height when crimped), which can make them a tough fit for some devices.

    3. Re:Cat6 by Holmwood · · Score: 5, Informative

      Foresight certainly helps. I wired my home twelve years ago with 622 Mbit/s teflon-coated copper twisted-pair ATM wiring. It was the best I could easily (and cheaply since it was left over from a large commercial project) obtain. Except as noted below, since then, I've detect no material degradation in cable testing, and, needless to say, it handled the leaps from 10 Mbit/s (1997) to 100 Mbit/s (2002) to 1 Gbit/s (2009) with no difficulties.

      According to a new (borrowed) cable tester, all the runs look capable of sustained 10 Gbit/s.

      At current rate of progress in speed that should take me at least to 2021 before I start noticing that I'm no longer keeping up.

      Of course with my luck, in my area, broadband will still probably be 10 Mbit/s and capped at 90 GB/month.

      In my (admittedly limited) observations, you can have about four sources for run destruction:
      1. Work hardening and breaking due to excessively sharp bending. (Be careful on insulation, and teflon coating = nice -- makes cable much harder to bend sharply)

      2. Oxidation problems especially at the terminal. I've had terminal problems with wiring in an indoor pool area (vapour barrier separating it from rest of the home). Salt water + generated chlorine seem not to like metal in general. People unlucky enough to have installed the Chinese contaminated drywall might have similar problems.

      3. Tension on cable (especially at terminal). Buildings shift, flex, settle, and twist. And not just in earthquakes. Competent installation helps here, especially if you have to redo a corroded terminal and need more run length.

      4. Renovation. Whether it's a nail through the wall, a drill in the wrong place, mistakes can happen.

      5. Animals. Squirrels getting into the attic managing to destroy infrastructure in a friend's house.

      I've not had problems with (1), (3), (4), (5) but friends have. I would assume (5) is not a big danger in most office environments, but one never knows. As I say, my experience is primarily limited to my home and those of friends who've also wired up. And my sole problems have been at the termination point, not with cabling itself.

      My advice is... buy good quality cabling -- better quality than you need. Don't get your installs done by cowboys, and try to think ahead.

      Tough advice sometimes to follow when you don't control the budget.

      -Holmwood

    4. Re:Cat6 by Walpurgiss · · Score: 5, Funny

      Rather than standard cat6, get Denon's super high fidelity cable. http://www.usa.denon.com/productdetails/3429.asp

      "AK-DL1

      $499.00

      Denon's 1.5 meter (59 in.) proprietary ultra premium Denon Link cable was designed for the audio enthusiast. Made from high purity copper wire and high performance connection parts, the AK-DL1 will bring out all the nuances in digital audio reproduction from any of our Denon DVD players with the Denon Link feature connected to a Denon Link enabled Denon A/V receiver. The AK-DL1 employs high level tin-bearing alloy shielding not typically available in commercial cabling, to eliminate data loss caused by noise. Additionally, signal directional markings are provided for optimum signal transfer. Attention to detail when building this cable was used by employing high quality insulation and woven jacketing to reduce vibration and to add durability. Rounded plug levers help prevent breakage.

      For operational and technical assistance 24/7, use our self help Online Support Center, where answers to many common questions can be found."

      If it's good enough for high fidelity audio reproduction, it should be good enough for our crappy data only needs. /smirk

    5. Re:Cat6 by Vancorps · · Score: 4, Insightful

      You seem to be confused with link speeds versus transfer speeds which can be very different.

      I'm sorry but 1Gbps is not equal on all hardware. Some hardware isn't even capable of going that fast, see the vast majority of consumer oriented network cards that come 10 for $1. As much as I love those realteks they are slow. Compared that with a server class NIC and you get dramatically different amounts of throughput.

      Hardware matters a lot and so does cabling. Just because you aren't getting errors doesn't mean you're going as fast as possible given your wiring and in my experience good luck getting actual gigabit speeds over Cat5 or Cat5e. Cat5e can at least do it over short distances like say 20' but much past that and your performance will indeed drop. It's easy to measure. Create a ramdrive on an ftp server and put a single large file in the ramdrive. Now initiate transfer to ramdrive on the other end. I have to transfer multiple terabytes when I arrive back at HQ after events so I notice those little performance differences.

      Of course since the bad old days I have moved on to fiber which is proving to be much more resilient to new technology.

    6. Re:Cat6 by atamido · · Score: 5, Insightful

      Yes, transfer speeds can vary greatly depending on the hardware being using, including the Ethernet controller, bus, CPU, drivers, etc.

      No, transfer speeds will NOT vary for two cables with the same 1000BASE-T link and no Ethernet transmission errors. I'd suggest you get some hardware that lets you monitor for Ethernet transmission errors (not TCP/IP errors) and run your test again.

      A 100M Cat5e cable will transfer at the same rate as a 100M Cat6 cable IF there are no transmission errors. In my experience, a well terminated Cat5e cable does not get regular Ethernet transmission errors with a 1000BASE-T link.

  2. Yes by oldhack · · Score: 5, Funny

    For best performance, replace it with a genuine high performance cable like this: http://www.usa.denon.com/productdetails/3429.asp

    --
    Fuck systemd. Fuck Redhat. Fuck Soylent, too. Wait, scratch the last one.
    1. Re:Yes by gavron · · Score: 5, Funny
      They got directional signal markings. It's what cables need.

      Brawndo, the thirst-tamer!

    2. Re:Yes by Anonymous Coward · · Score: 5, Funny

      They got directional signal markings. It's what electrons need.

      Brawndo, the thirst-tamer!

      Fixed that for ya :-)

    3. Re:Yes by Charles+Dodgeson · · Score: 4, Funny

      Agreed. $500 isn't too much to pay for an ethernet cable when your audio depends on it. I keep mine next to my DVD Rewinder.

      --
      Prime numbers are exactly what Alan Greenspan says they are -S. Minsky
    4. Re:Yes by Burkin · · Score: 4, Funny

      Yes, but that will do you no good if your CD is magnetized! You need to rush out and buy a CD demagnetizer to get the full audio experience!

      http://www.gcaudio.com/cgi-bin/store/showProduct.cgi?id=190

    5. Re:Yes by rlh100 · · Score: 5, Funny

      Oh yes. The high purity copper and alloy tinned shielding make a *HUGE* difference to my digital audio. I find that it transmits the ones and zeros with much higher and crisper definition. The braided cloth covering really does reduce vibration on the cable. I find my music is much more in tune and never wavers due to cable vibration. I am also sure that the electrons flowing in the right direction for the cable are the reason my is sound bigger with more warmth. And don't get me started on the improved imaging. I now know exactly where the sound is coming from. Fantastic, definitely five stars.

      I think these high definition Ethernet cables made as much an improvement as my $100 WattGate IEC power cords did. I am amazed at how replacing 6 feet of power cord can negate the ill effects that hundreds of feet of plain copper house wiring has on my AC power. Truly amazing sound.

      I am currently saving up for a set of triple ought (000) 99.999% pure silver speaker cables. I have been told by my audiophile sales person that these cables will allow me to hear the sound before it leaves the speakers. My only concern is that these dual 3/8" diameter cables are a bit heavy for my floor.

      Al Phile

              "More money than brains"

  3. Re:So I got a new sink..... by brian1078 · · Score: 5, Funny

    Should I have a plumber re-run copper all over my house?

    maybe if your new sink is capable of 1000 gpm (gallons per minute) and the pipes can only provide 100 gpm. but that's only if you care about using your new sink to its full potential.

  4. The officials at Monster Cable say.... by Chas · · Score: 5, Funny

    You should replace your tired old CAT5 with brand new, all-gold Monster-CAT6+++++++!

    Only $1000 a foot, starting in 10 foot increments!

    --


    Chas - The one, the only.
    THANK GOD!!!
  5. On a practical level . . . by taustin · · Score: 4, Insightful

    I am responsible for a 17 location VPN base WAN for a retail chain. We use Cat5e for everything, but in the end, it hardly matters, because Cat3 at 10 mbps is still over four times faster than the T-1 that it talks to the outside world with.

    But we don't work with large files internally, even here in the corporate office. If one is working with gigabyte sized files on a regular basis, on a local network, it would matter.

  6. Back in the day by SnarfQuest · · Score: 5, Funny

    Obligatory:

    When it was installed, your old cable had to run signals uphill through the snow, both directions. They didn't have electrons back then, they had to nake do with quarks. Time hadn't been invented yet, so the direction and speed of network traffic was hard to estimate.

    --
    Who would win this election: Andrew Weiner vs Andrew Weiner's weiner.
  7. "get old"? by nine-times · · Score: 4, Informative

    I'm not sure what would "get old" exactly. It's insulated copper, so I think it should be good so long as they aren't damaged. If anyone knows better, feel free to correct me.

    If you want to be sure, though, test them. Transfer files over your network. If the connection is bad, you can try replacing the cable and see if that works. But the fact that Cat6 is out doesn't mean you have to rush out and replace all your CAT5e cables, especially if you're only dealing with normal 100mbps connections. But I use CAT5e for 1gbps connections, and that seems to work fine.

  8. Gold plated baby! by Rosco+P.+Coltrane · · Score: 4, Insightful

    These people should be able to help you.

    Seriously though, what strange question. Either the cable works and you're happy with the bandwidth it provides, or it stops working and you replace it, or you want to upgrade it. What's the complication here?

    --
    "A door is what a dog is perpetually on the wrong side of" - Ogden Nash
    1. Re:Gold plated baby! by duplicate-nickname · · Score: 4, Insightful

      How is this insightful? Gigabit only requires Category 5 cabling.

      http://en.wikipedia.org/wiki/802.3ab

      --

      ÕÕ

  9. Re:So I got a new sink..... by Lord+Ender · · Score: 5, Funny

    It's not pipes. It's a series of tubes.

    --
    A slashdotter who didn't build his own computer is like a Jedi who didn't build his own lightsaber.
  10. Consider things carefully by WindBourne · · Score: 5, Funny

    If you do not, then cracks will appear and bits will start to drip from it. Soon, that drip will become bigger and you will have bytes dropping out. Cheaper to replace them now, then to lose all those bytes. I can be over there next week to replace them all for a low low price.

    --
    I prefer the "u" in honour as it seems to be missing these days.
    1. Re:Consider things carefully by thewils · · Score: 5, Funny

      Soon, that drip will become bigger and you will have bytes dropping out

      then you'll soon be up to your asses in raging torrents.

      --
      Once I was a four stone apology. Now I am two separate gorillas.
  11. No by Sycraft-fu · · Score: 5, Insightful

    Do not replace network cables just to do it. That is a waste of time and money Replace them in two situations:

    1) You are moving to a faster signaling speed and need better cabling. 10mbps requires Cat-3, 100mbps requires Cat-5, 1000mbps requires Cat-5e. Do not run higher speeds on lower standards, it works sometimes but often it "works" in that you get link but there's all kind of errors.

    2) A cable has a fault. Sometimes they will break because of strain. In this case, you need to replace them to make them work.

    Barring that, keep the cable you have. No reason to replace it just for fun. Also no reason to upgrade to new standards without a reason. It isn't as though it makes shit work better. 10mbps is 10mbps no matter if it is on Cat-3 or Cat-6. Also sometimes you get standards that aren't useful. Cat-6 is likley to never be useful for anything. 1gbps only needs Cat-5e, and 10gbps is likley to require Cat-6a. So if you upgraded a Cat-5e network to Cat-6 to prepare for faster speeds, well then you probably wasted your money and will have to upgrade again to Cat-6a if you want 10gbps.

  12. Re:So I got a new sink..... by infinite9 · · Score: 4, Funny

    maybe if your new sink is capable of 1000 gpm (gallons per minute) and the pipes can only provide 100 gpm. but that's only if you care about using your new sink to its full potential.

    The bathroom stalls where I work are always full. There's not enough toilets for the number of butts. They could certainly benefit from upgraded bathroom bandwidth.

    --
    Disconnect your television. Do your own research. Draw your own conclusions. They're probably lying. Don't be a sheep.
  13. Re:So I got a new sink..... by JustOK · · Score: 5, Funny

    its the interfaces, not the bandwidth

    --
    rewriting history since 2109
  14. You know the old adage by raddan · · Score: 4, Insightful

    "If it ain't broke, don't replace it with Cat6."

    Seriously, replacing cable is gigantic pain in the ass, when you could be doing better things with your time. Not to mention, it's expensive if you have a large enough installation-- this is why people are spending so much to keep Cat5e creaking along.

    If it's working, and you're happy with it, keep it. If you need something faster, or it doesn't work anymore, or you need to meet new fire codes, well, that answers your question.

    Remember, wires are solid state electronics. There's not much to go wrong there unless you're in extreme environments.

  15. Re:So I got a new sink..... by brian1078 · · Score: 5, Funny

    The bathroom stalls where I work are always full. There's not enough toilets for the number of butts. They could certainly benefit from upgraded bathroom bandwidth.

    yeah, I'm sure the bandwidth (drain pipe) is large enough for all the shit. It sounds more like they need to increase the number of connections allowed.

  16. We Replaced Our Type 1 Cable by slipnslidemaster · · Score: 4, Funny

    We replaced all of our Type 1 cabling at my company after the tokens started falling out.

    --


    "What the hell is an aluminum falcon?"
  17. Copper vs New Materials by Nuriko+Yanagi · · Score: 4, Interesting

    I kind of took this article more to be suggesting that we should be looking at newer data transmission technologies and materials - not so much continuing in a line, all involving copper.

    There are some recent reports released stating that *really* common elements used in technology are about to become exhausted resources - most in the next 10 years, but some as soon as 4 years from now.

    For instance, at our current rate of consumption, Indium will be exhausted in four years. Indium is used for current generation LCD displays, among other things.
    Gold and copper are in the same boat. The US already has closed down most of its gold mines, and all of its copper mines because they're not economically viable to mine for anymore. Predictions put gold and copper at exhausted in around 10 years.
    And none of these projections take into account population growth or new technology demands. It's only at "current consumption rates".

    In other words:

    Should we be looking to upgrade cabling to fiber optics or other mediums for transmission of data, so that we can begin reclaiming copper to be used in more essential capacities?

  18. Overkill... by volxdragon · · Score: 5, Insightful

    Bull - you can do Gig-E (IEEE 802.3ab) perfectly fine up to the 100 meter spec over regular old CAT-5 - http://en.wikipedia.org/wiki/Gigabit_ethernet. You don't need CAT-5e or CAT-6 unless you have incredibly shitty cable, splices, runs approaching max length, or too many patch panels along the route (IE, a crappy install in the first place).

    Now, I personally use shielded CAT-6 for everything, but I believe in overkill :)

    1. Re:Overkill... by Vancorps · · Score: 5, Informative

      While you can link at those speeds with Cat5 you cannot actually get those speeds. Usually it tops out about 200-400mbit for me when I've tried. For most uses that's perfectly fine but in some cases it's not like my entire graphics and video editing departments. Servers are all connected with Cat6 if they use a lot of bandwidth.

      I ran into this problem in Vegas as the place only had Cat5 connecting all the rooms to their closets so I had to use LACP trunking to get my bandwidth up.

    2. Re:Overkill... by QuantumRiff · · Score: 4, Interesting

      I have had all sorts of problems at work with my cabling.. All sorts of stuff worked great with the initial 10Mbt network. Now it is getting flaky at even 100MB, let alone gigabit. Occasionaly, we'll troubleshoot a wire, take off the faceplate at the wall, and find about 4-5 inches of unsheilded wired before its punched into its jack. Sometimes, its just one pair or two. I actually had a cable that someone made longer, by stripping the wires, twisting them together, and using MASKING tape to hold them together. That one was a treasure to find. Now, keep in mind, 80% of my cabling is awesome, and fully to spec. However, i'm guessing one of the guys working on the team that installed this cabling, long before I came, was of the "good enough" mentality, and its costing quite a bit to fix now.

      --

      What are we going to do tonight Brain?
    3. Re:Overkill... by troll8901 · · Score: 5, Funny

      ... I had to use LACP trunking to get my bandwidth up.

      I had a mental image of you sitting by the wiring closet, along the hotel corridor, staring intensely at your laptop.

      Wearing only a towel.

    4. Re:Overkill... by Sandbags · · Score: 5, Informative

      5 and 5e are only rated for 100MHz per pair, so although you can get link speed aggregated at 1000bT, your max throughput due to crosstalk, signal reflection, and EMI is going to limit your switch to a speed closer to 300-400Mbit. Many switches will detect Cat-5 issues and downgrade your link connection automatically on problematic runs.

      Connector quality has more to do with the connection quality than the cable itself. 5e simply has tighter specs to maintain. Really, there's not much of a difference, especially is you're using good patch panels.

      Cat 6 runs 250MHz per pair, tru gigabit speeds are supported.

      10G over copper is most commonly limited to 15M, and requires special 4 lane copper cabling, not Cat6 cabling. It's similar to Infiniband in design. A Cat 6 option was later offered, though few companies support this format. It's limited to 66m, and suffers similar bandwidth issues due to signal quality that running Gig-e over Cat-5 exhibits. Cat6a cabling can be used for 100m 10G deployments. Note this requires 650MHz Cat 6 cable ends, not 250MHz cat 6 cable ends as are normally deployed, for which there is a difference, and also requires 10G rated patch panels. Cat 6 cable can come in one of 3 thicknesses (guage). only one of these is commonly reccomended for 10G speeds.

      Cables do go bad over time, due either to environmental factors or movement. Exposure to direct sunlight is bad fort cabling. Non-constant temperatures is also a cause of degredation.(cables in plenem space or inside walls tend not to remain at constant temperatures). Oxidation of the copper connector is the most common failure. higher quality cables and patch panels use silver, gold, or other corrosion resistant metals for this reason. Many cables are also made with lower quality plastics that simply fail over time (some are practically designed that way I sometimes feel). When the plastic fails, the cables corrode quickly.

      More often I find a switch port fails before a cable (usually because someone plugged something in they should not have, or a charge makes it way into the cable due to being too close to a power cord, or long term exposue to magnetic fields causes elecrical resistance and damages the switch over time.

      typically, I'd leave cables in place until a hardware upgrade or data bottleneck justifies the change. ALLWAYS use high quality cables rated for the installation location. lower guage (thicker copper) are generally better, but they should ALLWAYS be within spec. Buy cables from companies that offer 20 year lifetime warranty. (Hitachi, Mowhawk, etc) Have them installed by professionals who back that warranty and use properly rated panels and punch downs and you should have no issues. Anytime you;re running cables, allways run a class of cable 2-3 tiers better than your current needs, and for workstation drops or other complicated runs, allways run spares (the labor typically costs more than the cable, and running 2 or 3 at once costs less than 1 now and 1 later). Use cable trays or hooks EVERYWHERE, never let cables lie on ceiling tiles or underneath floors in channles.

      This sounds like overkill, and probaly is for a small business, but when you have 14,000 desks in your copmpany (most with 2 netowrk and 2 phone drops) and over 3,500 servers, labor to replace cabling tallies in the millions of dollars...

      --
      There is no contest in life for which the unprepared have the advantage.
    5. Re:Overkill... by Kintanon · · Score: 5, Interesting

      That's what happens when ELECTRICIANS run your data cable.
      We came in behind an electrician that had taken every cable in the wiring closet, stripped the shielding off to about 1 foot from the wall, and neatly bundled each color of wire pairs together for about 100 cables. So we had a huge bundle of blue, then one of blue/white, then one of orange etc... pairs.
      Same guy tried to run network jacks in serial the way you can do telephone cable or electrical.
      Same guy would strip 4-6 inches of shielding off before punching down (incorrectly) at the jacks.

      Electricians just see it as low voltage electrical. The master electrician running the crew might know the difference, but the apprentice who is actually doing the work has no clue.

      So please, hire a real data wiring company to run your cables.

      --
      Check out JoshJitsu.info for Brazilian Ji
    6. Re:Overkill... by Bruce+Perens · · Score: 5, Informative

      Although shielding is nice to have, it's not necessary for network cable because network cable is balanced twisted pair. Indeed, most high-performance network cables are not available with shielding, they can't maintain the spec with a shield in the jacket. It might be that your cable is older.

      If you do have shielded cable, don't ground both ends!!! Bring all cables at one end to a common ground, and let the other end float. Otherwise, you will create a ground loop and actually make the noise worse.

    7. Re:Overkill... by lgw · · Score: 5, Informative

      Grounding one end makes the shielding at the ungrounded end an efficient antenna, and can actually increase the radiation from the cables.

      Cable shielding isn't a good way to avoid inteference with the signal on the cable, and isn't a good way to avoid radiation by the signal on the cable, unless properly terminated for one specific frequency (or narrow frequency range). One or both ends of the shielding would need to be coupled to case ground by a capacitor chosen for the frequency that you want to shield.

      Shielded cable at this frequency is likely to cause more harm than good. There's usually little need to shield against common-mode interference, and I've never heard of shielded cable being used in a TEMPEST set-up (carefully matching impedances is the best way to avoid emissions, creating giant gorund loop antennas is not).

      --
      Socialism: a lie told by totalitarians and believed by fools.
    8. Re:Overkill... by SCPRedMage · · Score: 4, Informative

      Hate to nit-pick, but UTP means UNSHIELDED twisted pair.

      So, yeah, how did that shielded unshielded twisted pair work out for ya?

      --
      My sig can beat up your sig.
    9. Re:Overkill... by evilkasper · · Score: 4, Insightful

      Truthfully if you think you need shielded, look at fiber, the prices have come down, and while copper isn't as expensive as it was a few months back it is still up there. You'll shell out a bit more but you'll have a better network for it.

    10. Re:Overkill... by plover · · Score: 4, Funny

      So, yeah, how did that shielded unshielded twisted pair work out for ya?

      Kinky.

      --
      John
    11. Re:Overkill... by mysidia · · Score: 5, Informative

      He said FTP, which is also known as S/UTP, screened unshielded twisted pair, or "fully shielded" twisted pair.

      The difference between FTP and STP is that in STP, each cable pair is shielded.

      FTP has only an overall shield that covers all the pairs (each pair isn't individually shielded).

      So FTP _is_ shielded UTP.

    12. Re:Overkill... by Nefarious+Wheel · · Score: 4, Funny

      I tend toward wireless for the home network. If I need to replace the air, I open a window.

      --
      Do not mock my vision of impractical footwear
    13. Re:Overkill... by Anonymous Coward · · Score: 5, Informative

      5 and 5e are only rated for 100MHz per pair, so although you can get link speed aggregated at 1000bT, your max throughput due to crosstalk, signal reflection, and EMI is going to limit your switch to a speed closer to 300-400Mbit. [...] Cat 6 runs 250MHz per pair, tru gigabit speeds are supported.

      That is incorrect. Gigabit Ethernet (1000BASE-T) uses the same bandwidth as Fast Ethernet. The higher speed is achieved by using
        1) all four pairs (Fast Ethernet uses two),
        2) each pair in both directions (Fast Ethernet uses one pair to send, one to receive), and
        3) a more efficient encoding (more bits per baud).
      The full Gigabit Ethernet speed is specified for Cat5 cables.

    14. Re:Overkill... by wilby · · Score: 5, Insightful

      Please don't blame "Electricians".

      Whoever did your cabling was unqualified to do the work he was hired to do. (Usually the the fault of whoever hired them.)

      There are several electrical contractors who are qualified to do data work.

    15. Re:Overkill... by RajivSLK · · Score: 4, Interesting

      Whoever did your cabling was unqualified to do the work he was hired to do. (Usually the the fault of whoever hired them.)

      I don't follow... When I get a quote from somebody who claims to be capably trained for certain task how is it my fault when he screws up? The long and short of it is that thousands of people every year get screwed over by trades people who claim skills they don't have (Some of the scamers are quite good at it too) and the blame lies mostly with these unscrupulous people.

    16. Re:Overkill... by SuperMonkeyCube · · Score: 4, Interesting

      I will second wilby's comment and say that Electricians are not the problem. Any licensed contractor that's worth his salt will know what his capabilities are and act accordingly. The BICSI standards have been in place for a long time, and BICSI has done a great job getting the word out to both electricians and low voltage contractors about how to do things to industry standard. If someone wires CAT5 like it's something else, then you have a dumbass problem, not an electrician problem. All of the jack vendors have done a great job disseminating information about how to do CAT5, and several have certified installer programs aimed at getting people putting together a system, not just wires. If field personnel cannot avail themselves with current information then I wouldn't even trust them to put in a fluorescent dimmer or a thermostat made in the last ten years.

    17. Re:Overkill... by adolf · · Score: 4, Informative

      You talk about grounding like folks used to talk about SCSI termination[1].

      The reality is far simpler, and there's no goat's blood required: Use shielded wire where it makes a difference. Ground it at one end (or in the middle if that's what the situation dictates, but under no circumstances at more than one point).

      And then, have a beer. While imbibing, rejoice in the fact that one's cell phone has ceased ringing with voices proclaiming connection issues.

      [1]: SCSI buses should be terminated exactly twice; once at each end of the bus. If you have more than two terminators, they are in the middle of the bus, or your "bus" has more than two ends, you've done it all wrong and need to start over. Same with TV coax, radio coax, 10base2, or any other transmission line medium.

  19. Re:So I got a new sink..... by Red+Flayer · · Score: 5, Funny

    The bathroom stalls where I work are always full.

    OF WHAT?! Ewww...

    There's not enough toilets for the number of butts. They could certainly benefit from upgraded bathroom bandwidth.

    Instead of increasing bandwidth, what about using traffic-shaping instead? I'm not sure if this is something that could be automated, or if it would need to be done manually [shudder].

    Obviously, to anyone familiar with overselling is aware of, the problem is not the number of users for the bandwidth assigned. The problem is likely that 2% of your poopers consume (bad word choice, I know) 98% of your bandwidth, resulting in a logjam of epic proportions just after lunch. They key would be to cap their usage, so that everyone else can use the bandwidth in moderate amounts.

    Most likely, your excessive users are illegally logsharing anyway. There can't be any legitimate reason for someone to spend 4 hours a workday on the crapper, can there?

    --
    "Trolls they were, but filled with the evil will of their master: a fell race..." -- J.R.R. Tolkien on Olog-hai
  20. Re:So I got a new sink..... by mikael · · Score: 4, Funny

    Yes, but make sure all the connectors are gold plated - it helps to improve the quality of the water.

    --
    Vintage computer adverts: http://www.vintageadbrowser.com/computers-and-software-ads
  21. The largest danger to cable longevity remains mice by dyfet · · Score: 5, Funny

    Any category of "cat" can certainly help with that...

  22. Re:So I got a new sink..... by Shadow+of+Eternity · · Score: 4, Funny

    No, you don't get it. This is not something that you just dump something on. It's not a big truck. It's a series of tubes. And if you don't understand, those tubes can be filled and if they are filled, when you put your shit in, it gets in line and it's going to be delayed by anyone that puts into that tube enormous amounts of material, ENORMOUS amounts of material.

    --
    A bullet may have your name on it but splash damage is addressed "To whom it may concern."
  23. Re:So I got a new sink..... by greyhueofdoubt · · Score: 4, Funny

    Play one of those halloween scary sound CD's on repeat, very loud, all day. It's not so much scary as it is unsettling, and people will avoid spending time in there unless it's an emergency.

    Alternate titles:

    pigs being slaughtered
    Jokes, except the punchline is cut out
    one cat, in heat, wailing and meowing to be let out
    classical out of one speaker, the sound of crazed laughter out the other
    the sound of two balloons being rubbed together
    random gunshots spaced 30 sec-90 sec apart. LOUD.
    highly amplified signal coming from a microphone near the occupant's toilet
    ticking clock that randomly speeds up and slows down
    the soundtrack from zombo.com

    I don't know. I think my idea would work.

    --
    No offense, but I've stopped responding to AC's.
  24. Re:So I got a new sink..... by Hognoxious · · Score: 5, Funny

    pipes are tubes.

    Do you think Sherlock Holmes would have solved so many cases if he smoked a tube? No, Watson, he fucking well wouldn't.

    --
    Confucius say, "Find worm in apple - bad. Find half a worm - worse."
  25. Re:So I got a new sink..... by JWSmythe · · Score: 4, Informative

        Well, oddly enough I did IT work for a plumbing company. One of the things they did was "repipes" of residences. Usually they were done due to recurrence of leaks. Copper pipe corrodes from the inside because of chemicals in the water (like chlorine). Sometimes it was done where there was minimal water flow, when corrosion or sediment didn't wash away, but built up.

        So, if you got a new sink because you were changing the rusty faucets and then you found your water flow wasn't improved, you may be a candidate for repiping part or all of your home. It could just be buildup in the shutoff valve too.

        But to stay on topic......

        I've seen people run network cables over or under their carpet. They start getting degraded service as people walk on it. Yes, those need to be changed. Properly run network cables (in the walls, with no rat infestations to eat the cables) don't generally need to be changed, unless something else happened. And I have seen network cards that handle regular CAT5 at speeds over 100Mb/s with 1000baseTX interfaces. Sometimes you can just reterminate the cables because the "spare" 2 pairs were never wired right, assuming those extra wires are ok (i.e., the installer didn't yank the cable through and bugger it up.

        But, realize (to the OP) that there are limitations to GigE on a computer. Most of the time in the real world, you won't see 1000Mb/s. It's dependent on the switching hardware, PCI/PCIe bus, hard drives being read from/to, etc, etc, etc....

    --
    Serious? Seriousness is well above my pay grade.
  26. Re:Real question by couchslug · · Score: 4, Funny

    ""Should I make work for myself on a complicated, invasive, lengthy, and hard to stop project so I can continue to justify my job in a recession?"

    Fuck yes!

    "If you're going to do anything, upgrade to fiber."

    Thanks for the tip!

    --
    "This post is an artistic work of fiction and falsehood. Only a fool would take anything posted here as fact."
  27. Re:So I got a new sink..... by Znork · · Score: 4, Insightful

    And I have seen network cards that handle regular CAT5 at speeds over 100Mb/s with 1000baseTX interfaces.

    I got a leftover cable spool from a friend and didn't really check it when I laid it in for my 100mbit network. I switched to gigabit, and a year or two after that I looked at the spool and noticed it was CAT5; the only time I'd ever had any trouble with it was with a bad crimp or two that hadn't been exposed on 100mbit.

    CAT5e should be good for 100 meters of GigE; that Cat5 can handle GigE over the more common shorter distances isn't really that strange. Upgrade any long distance cable and ignore the rest unless there's a problem.

    Now, for 10GBaseT or 40GBaseT it'll be time to look things over, Cat6a through Cat7a provide performance for 500-1000MHz compared to the 100MHz of the Cat5 offerings.

  28. Re:So I got a new sink..... by therufus · · Score: 4, Funny

    I read "Should Network Cables Be Replaced" and thought maybe I could learn something and gain some insight. Instead I'm treated to the most bizarre toilet analogy of epic proportions.

    This may be the best reply thread in the history of /. IMHO.

    THANKYOU /.'ers for making my day! :D

    --
    You moved your mouse. Please restart Windows for changes to take effect.
  29. Re:So I got a new sink..... by Anonymous Coward · · Score: 4, Funny

    Maybe they should just add a wireless hotspot and allow anonymous connections!

  30. Re:So I got a new sink..... by CheeseTroll · · Score: 4, Funny

    Oh sure, blame the content providers!

    --
    A post a day keeps productivity at bay.
  31. More things to look out for.... by managerialslime · · Score: 4, Informative

    Not only can your gear affect your speeds, but conflicts with speed auto-sensing can wreak havoc.

    We recently swapped out some older edge switches in one site for a beautiful new CISCO core switch. Within days, the help desk had reports that some users' network performance had gone from fine to terrible. (Not our intent.)

    As it turns out, a boatload of older NICs were mishandled by the new switch which downgraded speeds, communicated in half-duplex, and even then continually reset the connection.

    Had the users not complained, we never would have known there was a problem.

    As it turns out, each port on the core switch can be manually set to a fixed 100mb full duplex (and ignore auto-sensing) which then operates just fine.

    So much for plug-n-pray.

    --
    Live Long and Prosper - Thanks Leonard. You are missed.
  32. Re:So I got a new sink..... by wildstoo · · Score: 5, Funny

    This may be one instance where REDUCING the amount of fibre in the network may help ease the load.